BREAKDOWN RECTIFICATION OF FLUID BED DRYER

To  describe  a  standard operating  procedure  for  breakdown    rectification of fluid bed dryer.

Sharing is caring, show love and share the thread with your friends.

Description

1.0 PURPOSE:
    
    To  describe  a  standard operating  procedure  for  breakdown    rectification of fluid bed dryer.
    
2.0    SCOPE:
    
    The  standard  operating  procedure describes  in  detail  the  method of breakdown  rectification of fluid bed dryer.
    
3.0    RESPONSIBILITY:
    
    The  responsibility of breakdown  rectification of  fluid  bed   dryer lies with the  staff of rank not lower than  maintenance   supervisor of maintenance department. 

The responsibility of preparing, reviewing  and approving  the  standard  operating  procedure lies with the Manager  -  Maintenance,  Head of Production and Head of QAD respectively.
    
4.0    METHOD:
    
4.1    Improper fluidisation:

4.1.1    This  can happen due to blower not functioning  properly.

4.1.2    Take out the product  container and retarding chamber.

4.1.3    De link the finger bag from the hook.

4.1.4    Check  the impeller of the blower.  If the impeller blades are   found broken, replace the impeller.

4.1.5    Fix the finger bag, retarding chamber and product container.

4.1.6    Start the blower and check for proper fluidisation.

4.2    Chocking of bottom mesh of product container :

4.2.1    Chocked mesh to be dechocked using compressed air/water.

4.3     Chocking of finger bag filters:

4.3.1    This can be rectified by shaking the bag thoroughly by  manual   shaking arrangement or replace with new finger bag as follows.

4.3.2    Take-out the product container from the shoe.

4.3.3    Take-out Fluidising/Retarding chamber.

4.3.4    Delink the finger bag from the hooks.

4.3.5    Fix the  new finger bag to the hooks.

4.3.6       Fix the Fluidising chamber and product container.

4.4         Improper drying or more drying time:

4.4.1    This  may happen due to poor fluidisation (this may be due  to  creation of low suction by blower), low temperature (This  may  be due to less steam pressure, malfunctioning of steam trap).Check for any of the above problem and rectify accordingly.

5.0     RECORDING:

    The responsibility of recording breakdown rectification in the   history  card   as per SOP lies with staff of rank  not  lower  than the maintenance Engineer.