1.0    PURPOSE:
    
    To describe a  standard operating  procedure  (SOP) for  performing refluxion.
    
2.0    SCOPE:
    
    The SOP describes in detail the method of refluxion.
    
3.0    RESPONSIBILITY:
    
    The responsibility  of carrying out refluxion as per the SOP lies with the staff of the rank not lower than operator of the production department.
    
    The responsibility of preparing, reviewing and approving the SOP lies with the Officer (Production), Head of Production and Head of QAD  respectively.
    
4.0    METHOD:
    
4.1    Empty  the jacket of the reactor. Give chilled water supply to the condenser. Open vent valve of distillation line.
    
4. 2    Close jacket drain valve, open steam trap and open steam inlet valve. Apply steam heating slowly to the jacket.
    
4. 3    Slowly  heat the mass till reflux starts and which can  be  observed from the viewglass.
    
4.4    Open the  return valve  from the condenser to the reactor  once  the refluxion has started.
    
4.5    Adjust  the position of steam valve by proper manipulation so that reflux will be continued.
        
5.0    RECORDING:
    
    The reflux operation  will be recorded by the operator/supervisor in the batch manufacturing sheet.
    
    